Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. bras. ter. intensiva ; 34(3): 351-359, jul.-set. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1407751

ABSTRACT

RESUMO Objetivo: Desenvolver um ventilador mecânico invasivo simples, resistente, seguro e eficiente que possa ser utilizado em áreas remotas do mundo ou zonas de guerra, em que a utilidade prática de equipamentos mais sofisticados é limitada por questões de manutenção, disponibilidade de peças, transporte e/ou custo. Métodos: O dispositivo implementa o modo de ventilação mandatória contínua com pressão controlada, complementado por um simples modo assisto-controlado. Pode-se também utilizar a pressão positiva contínua nas vias aéreas. Ao se evitar o fluxo contínuo de oxigênio ou ar, minimiza-se o consumo de gases comprimidos. As taxas respiratórias e as relações de tempo de inspiração e expiração são determinadas eletronicamente. Além disso, conta com um alarme de apneia/falta de energia. Resultados: Os perfis de pressão foram medidos para uma série de condições, sendo considerados ajustáveis dentro de uma margem de erro de ± 2,5cmH2O, e foram considerados bem estáveis dentro dessa variação durante um período de 41 horas. Os parâmetros de tempo do ciclo respiratório foram precisos dentro de alguns pontos percentuais durante o mesmo período. O dispositivo foi testado quanto à durabilidade por um período equivalente a 4 meses. Os testes químicos e biológicos não conseguiram identificar qualquer contaminação do gás por compostos orgânicos voláteis ou micro-organismos. Em comparação com um ventilador bem estabelecido, o teste de ventilação em um animal de grande porte mostrou que este poderia ser ventilado adequadamente durante um período de 60 minutos, sem quaisquer efeitos negativos perceptíveis durante o período subsequente de 24 horas. Conclusão: Este projeto de ventilador pode ser viável após novos testes em animais e aprovação formal pelas autoridades competentes, para aplicação clínica nas circunstâncias atípicas anteriormente mencionadas.


ABSTRACT Objective: To develop a simple, robust, safe and efficient invasive mechanical ventilator that can be used in remote areas of the world or war zones where the practical utility of more sophisticated equipment is limited by considerations of maintainability, availability of parts, transportation and/or cost. Methods: The device implements the pressure-controlled continuous mandatory ventilation mode, complemented by a simple assist-control mode. Continuous positive airway pressure is also possible. The consumption of compressed gases is minimized by avoiding a continuous flow of oxygen or air. Respiratory rates and inspiration/expiration time ratios are electronically determined, and an apnea/power loss alarm is provided. Results: The pressure profiles were measured for a range of conditions and found to be adjustable within a ± 2.5cmH2O error margin and stable well within this range over a 41-hour period. Respiratory cycle timing parameters were precise within a few percentage points over the same period. The device was tested for durability for an equivalent period of four months. Chemical and biological tests failed to identify any contamination of the gas by volatile organic compounds or microorganisms. A ventilation test on a large animal, in comparison with a well established ventilator, showed that the animal could be adequately ventilated over a period of 60 minutes, without any noticeable negative aftereffects during the subsequent 24-hour period. Conclusion: This ventilator design may be viable, after further animal tests and formal approval by the competent authorities, for clinical application in the abovementioned atypical circumstances.

2.
Radiol. bras ; 54(6): 353-359, Nov.-Dec. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1422504

ABSTRACT

Abstract Objective: To present our clinical experience with percutaneous antegrade ureteral stenting. Materials and Methods This was a single-center retrospective study in which we reviewed the electronic medical records of patients who underwent percutaneous image-guided antegrade ureteral stenting between January 2016 and August 2020. We evaluated 90 patients (48 men). The mean age was 61.4 ± 15 years (range, 30-94 years). Patients were divided into two main groups: those with malignant neoplasms; and those with non-neoplastic disease. Technical and clinical success of the procedure were defined, respectively, as maintenance of the patency of the urinary tract, with a reduction in the degree of hydronephrosis, and as a reduction in the level of nitrogenous waste. Postprocedural complications were categorized as major or minor according to the CIRSE classification. Results: The study sample comprised 150 antegrade stenting procedures performed in 90 patients, most of whom had previously undergone retrograde stenting that was unsuccessful. The stenting was bilateral in 60 patients and unilateral in 30. Technical success was achieved in 143 (95.3%) of the procedures, whereas seven procedures (4.6%) were unsuccessful. Failed procedures were characterized by inability to place a stent or migration of a stent after its placement. Complications occurred in 12 (8.0%) of the procedures. Of those 12 complications, two were classified as major (bleeding) and 10 were classified as minor (lumbar pain or infection). The most common techniques used were the over-the-wire technique and the modified technique (in 58.0% and 42.0% of the cases, respectively). In seven cases (4.7%), a nephrostomy tube was inserted. Conclusion: Percutaneous antegrade ureteral stenting is a safe, effective method for the management of ureteral injuries and obstructions, due to malignant or benign causes, when the retrograde approach has failed.


Resumo Objetivo: Apresentar os resultados clínicos de 150 casos de inserção anterógrada de cateter duplo J. Materiais e Métodos: Foram revisados os prontuários eletrônicos de pacientes submetidos a inserção percutânea de cateter duplo J guiada por imagem entre janeiro de 2016 e agosto de 2020. Um total de 90 pacientes (48 homens e 42 mulheres; faixa etária, 30-94 anos; idade média, 61,4 ± 15 anos) foi incluído no estudo. Os pacientes foram classificados em dois grupos principais: neoplasia maligna e doença não neoplásica. O sucesso técnico e clínico do procedimento foi definido como a manutenção da perviedade da via urinária com redução do grau de hidronefrose e redução dos níveis das escórias nitrogenadas. As complicações pós-procedimento foram classificadas em maiores e menores, de acordo com o sistema de classificação CIRSE. Resultados: Foram realizados 150 procedimentos (90 pacientes) no período, sendo bilateral em 60 pacientes e unilateral em 30. Houve sucesso técnico em 143 casos (95,3%) e falhas em sete (4,7%), caracterizadas por migração e não progressão do cateter. Nossas taxas de complicações foram de 8,0% (12 casos), sendo dois maiores (sangramento) e 10 menores (principalmente dor lombar). As técnicas mais utilizadas para a inserção foram over the wire (58,0%) e modificada (42,0%). Em sete pacientes (4,7%) foi realizada nefrostomia percutânea. Conclusão: A inserção anterógrada do cateter duplo J é um método seguro e eficaz para o tratamento de obstruções uretéricas devidas a causas e lesões malignas e benignas, quando há uma falha na abordagem cistoscópica (retrógrada).

SELECTION OF CITATIONS
SEARCH DETAIL